call fit(1,1,1,0.0,.1,1) call fit(1,3,3,0.0,.1,1) call fit(2,1,2,0.0,1.,1) call fit(2,3,4,0.0,1.,1) call twissmatch(1,0.0,8.1909,10.,1) call twissmatch(3,0.0,88.1716,10.,1) call twissmatch(1,0.,8.1909,10.,1) call twissmatch(3,-0.,88.1716,10.,1) call fit(2,1,6,0.,1.,1) call fit(2,2,6,0.,1.,1) call twissmatch(1,0.,8.1909,10.,1) call twissmatch(3,-0.,88.1716,10.,1) Sequence ends at the edge of ALTS:B1 closer to ALTE:Q26 Coordinates of that on ART2082.dwg are: X: 1235498.125 mm Y: 2295750.00 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200211 - I have confirmed all distances in this sequence using ART2082.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the edge of ALTS:B1 closer to ALTE:Q26 Coordinates of that on ART2082.dwg are: X: 1235498.125 mm Y: 2295750.00 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. Sequence ends at the edge of ALTS:B4 closer to ALTS:Q5. Coordinates of that on ART2082.dwg are: X: 1216910.5 mm Y: 2314337.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200211 - I have confirmed all distances in this sequence using ART2082.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the edge of ALTS:B4 closer to ALTS:Q5. Coordinates of that on ART2082.dwg are: X: 1216910.5 mm Y: 2314337.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. ! FIT at the start of a periodic section call twissmatch(1,-2.1717,85.424,10.,1) call twissmatch(3,2.1717,85.424,10.,1) SK 20200225 - LPM9 position on ART2082.dwg is incorrect as per Suresh. using Q9 to LPM9 distance e-mailed to me by Suresh based on a manufacturer's drawing of LPM9 diagnostics box. ! FIT at the start of a periodic section call fit(1,2,1,0.,1,1) call fit(1,4,3,0.,1,1) ! FIT at the start of a periodic section call twissmatch(1,2.1717,85.424,1.,1) call twissmatch(3,-2.1717,85.424,1.,1) Sequence ends at the downstream edge of the ALTS:Q12 skimmer Coordinates of that on ART2082.dwg are: X: 1154157.875 mm Y: 2314337.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK - All optics positions verified 202000226 All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the downstream (closer to AGTY:Q13) edge of AGTNY:B4. Coordinates of that on ART2080.dwg are: X: 1693204.125 mm Y: 2262221.25 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. call FIT( 1, 1, 1, 0.000, 10.000, 1) call FIT( 1, 3, 3, 0.000, 10.000, 1)