SK 20200211 -I have confirmed all distances in this sequence relative to Q1 using ART2082.dwg. ALTIS:Q1-3 effective lengths confirmed by Suresh on 20200224. All other effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence appears to start near (but not exactly) ALTIS:EMIT at coordinates X = 1266498.875 mm Y = 2314337.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. Location of Q1X and Q1Y is false to allow for separate element of type ecb Q1 is actually a steering quad, so the steering is from asymmetry in the quad electrode voltages. ! FIT at the start of a periodic section call twissmatch(1,-2.1717,85.424,10.,1) call twissmatch(3,2.1717,85.424,10.,1) call fringeQ(0.0872,-0.0009,0.0298,-0.230) Sequence ends at the edge of ALTS:B4 closer to ALTS:Q5. Coordinates of that on ART2082.dwg are: X: 1216910.5 mm Y: 2314337.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200211 - I have confirmed all distances in this sequence using ART2082.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the edge of ALTS:B4 closer to ALTS:Q5. Coordinates of that on ART2082.dwg are: X: 1216910.5 mm Y: 2314337.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. ! FIT at the start of a periodic section call twissmatch(1,-2.1717,85.424,10.,1) call twissmatch(3,2.1717,85.424,10.,1) SK 20200225 - LPM9 position on ART2082.dwg is incorrect as per Suresh. using Q9 to LPM9 distance e-mailed to me by Suresh based on a manufacturer's drawing of LPM9 diagnostics box. ! FIT at the start of a periodic section call fit(1,2,1,0.,1,1) call fit(1,4,3,0.,1,1) ! FIT at the start of a periodic section call twissmatch(1,2.1717,85.424,1.,1) call twissmatch(3,-2.1717,85.424,1.,1) Sequence ends at the downstream edge of the ALTS:Q12 skimmer Coordinates of that on ART2082.dwg are: X: 1154157.875 mm Y: 2314337.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200225 - I have confirmed all distances in this sequence using ART2082.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the downstream edge of the ALTS:Q12 skimmer Coordinates of that on ART2082.dwg are: X: 1154157.875 mm Y: 2314337.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. ! FIT at the start of a periodic section call twissmatch(1,2.1717,85.424,10.,1) call twissmatch(3,-2.1717,85.424,10.,1) ! FIT at the start of a periodic section call twissmatch(1,-2.1717,85.424,10.,1) call twissmatch(3,2.1717,85.424,10.,1) SK 20200225 - LPM19 position on ART2082.dwg is incorrect as per Suresh. using Q19 to LPM19 distance e-mailed to me by Suresh based on a manufacturer's drawing of LPM19 diagnostics box. Sequence ends at the downstream edge of the ALTS:Q20 skimmer Coordinates of that on ART2082.dwg are: X: 1154157.875 mm Y: 2314337.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200225 - I have confirmed all distances in this sequence using ART2082.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the downstream edge of the ALTS:Q20 skimmer Coordinates of that on ART2082.dwg are: X: 1154157.875 mm Y: 2314337.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200225 - PM2 position on ART2082.dwg is incorrect as per Suresh. using Q2 to PM2 distance e-mailed to me by Suresh based on a manufacturer's drawing of PM2 diagnostics box. Sequence ends at the upstream edge (closer to ALTSW:B4) of the ALTW:Q33 skimmer Coordinates of that on ART2082.dwg are: X: 1032298.1875 mm Y: 2334597.25 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200225 - I have confirmed all distances in this sequence using ART2082.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the upstream edge of the ALTW:Q33 skimmer Coordinates of that on ART2082.dwg are: X: 1032298.1875 mm Y: 2334597.25 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200225 - LPM41 position on ART2082.dwg is incorrect as per Suresh. using Q41 to LPM41 distance e-mailed to me by Suresh based on a manufacturer's drawing of LPM41 diagnostics box. SK 20200225 - PM43 position on ART2082.dwg is incorrect as per Suresh. using Q43 to PM43 distance e-mailed to me by Suresh based on a manufacturer's drawing of PM43 diagnostics box. Sequence ends at the downstream edge of the ALTW:Q44 skimmer Coordinates of that on ART2082.dwg are: X: 1032298.1875 mm Y: 2446477.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200225 - I have confirmed all distances in this sequence using ART2082.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the downstream edge of the ALTW:Q44 skimmer Coordinates of that on ART2082.dwg are: X: 1032298.1875 mm Y: 2446477.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. ! FIT at the start of a periodic section call twissmatch(1,-2.1717,85.424,10.,1) call twissmatch(3,2.1717,85.424,10.,1) Sequence ends at the centre of the cross between ALTW:Q45 and AHRS:Q1 Coordinates of that on ART2082.dwg are: X: 1032298.1875 mm Y: 2466737.5 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 2020-02-25 - Distances in this sequence and sequences up to and through the HRS were done by Maire, a co-op student of Suresh in Fall 2019. ***NO distances have been confirmed in comparison to ART2082.dwg, just the start/end coordinates specified. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the centre of the cross between ALTW:Q45 and AHRS:Q1 Coordinates of that on ART2082.dwg are: X: 1032298.1875 mm Y: 2466737.5 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. call fringeQ(0.123,-0.005,0.044,-0.276) ! magnification factor betxstart=14.6873 ! cm betxend=betxstart/C1**2 emitx=0.0003 ! units ar cm-rad. xsz=sqrt(betxend*emitx) call FIT( 2, 1, 2, -0.0, 1.0, 1) call FIT(1,1,1,xsz,1000.,1) call fit( 1, 3, 4, -0.0000, 4.0000, 1) call fit( 1, 3, 3, 0.2449, 3.0000, 0) Sequence ends at the downstream edge (closer to AHRSN:B1) of the AHRS:Q13 skimmer. Coordinates of that on ART2082.dwg are: X: 1133898.5 mm Y: 2486997.25 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 202000226 - Distances verified comparing to ART2082.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the downstream edge (closer to AHRSN:B1) of the AHRS:Q13 skimmer. Coordinates of that on ART2082.dwg are: X: 1133898.5 mm Y: 2486997.25 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. Sequence ends at the upstream edge (closer to AHRSN:B4) of the ALTN:Q16 skimmer. Coordinates of that on ART2082.dwg are: X: 1154158.0 mm Y: 2466737.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 202000226 - Distances verified comparing to ART2082.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the upstream edge (closer to AHRSN:B4) of the ALTN:Q16 skimmer. Coordinates of that on ART2082.dwg are: X: 1154158.0 mm Y: 2466737.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. ! FIT at the start of a periodic section call twissmatch(1,-2.1717,85.424,10.,1) call twissmatch(3,2.1717,85.424,10.,1) ! FIT at the start of a periodic section call fit(1,2,1,0,1,1) call fit(1,4,3,0,1,1) Sequence ends at the upstream edge (closer to ALTN:B33) of the AVTE:DEFL0 skimmer. Coordinates of that on ART2081.dwg are: X: 1718849.2 mm Y: 1889773.875 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 202000225 - All distance confirmed in comparison to ART2081.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the upstream edge (closer to ALTN:B33) of the AVTE:DEFL0 skimmer. Coordinates of that on ART2081.dwg are: X: 1718849.2 mm Y: 1889773.875 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. Sequence ends at the upstream edge of the AVTE:DEFL14 skimmer Coordinates of that on ART2081.dwg are: X: 1719031.75 mm Y: 2044868.875 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200211 - I have confirmed all distances in this sequence using ART2081.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence ends at the upstream edge of the AVTE:DEFL14 skimmer Coordinates of that on ART2081.dwg are: X: 1719031.75 mm Y: 2044868.875 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. Sequence ends at the downstream edge of AVTEN:B4 Coordinates of that on ART2081.dwg are: X: 1700445.25 mm Y: 2068758.5 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200226 - I have confirmed all distances in this sequence using ART2080.dwg. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the downstream edge of AVTEN:B4 Coordinates of that on ART2080.dwg are: X: 1592957.25 mm Y: 2313020.25 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. ! FIT at the start of a low beta insertion call twissmatch(1,2.1717,85.424,1.,1) call twissmatch(3,-2.1717,85.424,1.,1) ! FIT at the start of a periodic section call twissmatch(1,-0.7153,139.8,10.,1) call twissmatch(3,-0.7153,139.8,10.,1) SK 20200226 - RFQ 's' was way off, so I've adjusted it based on design drawing. I've also reduced the length as it was then overlapping with upstream fit statement. RFQ position/lenth should be double checked. call fit(1,2,1,0.,1,1) call fit(1,4,3,0.,1,1) call fit(2,2,6,0.,1,1) SK 20200226 - while checking distances, slid the fit below to remain the same distance from AGTE:Q37. ! FIT at the start of a periodic section call twissmatch(1,0.,40.,1.,1) call twissmatch(3,0.,40.,1.,1) SK 20200226 - while checking distances, reduced PDT length from 950.16 mm to 945.12 mm to avoid overlap with preceding fit statement which would cause negative drifts. SK 20200226 - I **did not** confirm the EL38 effective length. Sequence ends at the downstream edge (closer to EBIS) of AGTC:B1 Coordinates of that on ART2080.dwg are: X: 1457596.125 mm Y: 2430017.00 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200330 - I have confirmed all distances in this sequence using ART2080.dwg. Sequence starts at the downstream edge (closer to EBIS) of AGTC:B1 Coordinates of that on ART2080.dwg are: X: 1457596.125 mm Y: 2430017.00 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. Sequence ends at the marker for 'AGTE EBIS' on ART2080.dwg Coordinates of that on ART2080.dwg are: X: 1385565.875 mm Y: 2430016.5 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200330 - I have confirmed all distances in this sequence using ART2080.dwg. Sequence starts at the marker for 'AGTE EBIS' on ART2080.dwg Coordinates of that on ART2080.dwg are: X: 1385565.875 mm Y: 2430016.5 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. Sequence ends at the upstream edge (closer to EBIS) of the AGTC:B1 as it turns towards the nier. Coordinates of that on ART2080.dwg are: X: 1457653.875 mm Y: 2429072.25 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK - All optics positions verified 20200210. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf 1.0" quads = 25.4 mm electrode => 35.12 mm effective 1.5" quads = 38.1 mm electrode => 47.50 mm effective 2.0" quads = 50.8 mm electrode => 60.59 mm effective Sequence starts at the upstream edge (closer to EBIS) of the AGTC:B1 as it turns towards the nier. Coordinates of that on ART2080.dwg are (measured using e drawings PRO): X: 1457653.875 mm Y: 2429072.25 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. 36 degree spherical bender, radius 254.0 mm. NIER spectrometer dipole, radius of curvature 360 mm, bend radius 90 degrees SK 20200210. Re-verifying positions based on ART2080, so I slid Q11:match-point forward so it is the same distance from Q11 as it was before, which is 136.288 mm. ! FIT at the start of a periodic section call twissmatch(1,2.1717,85.424,10.,1) call twissmatch(3,-2.1717,85.424,10.,1) ! FIT at the middle of a horizontal bender call fit(1,2,1,0.,10,1) call fit(1,4,3,0.,10,1) call fit(2,2,6,0.,10,1) Sequence ends at the downstream (closer to IGTA:B26) edge of the AGTC:Q28 skimmer Coordinates of that on ART2080.dwg are (measured using e drawings PRO): X: 1542157.125 mm Y: 2209962.5 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mmthe units given on drawing need to be divided by 25.4. SK - All optics positions verified 20200903. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the downstream (closer to IGTA:B26) edge of the AGTC:Q28 skimmer Coordinates of that on ART2080.dwg are (measured using e drawings PRO): X: 1542157.125 mm Y: 2209962.5 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. Sequence ends at the downstream (closer to AGTS:Q9) edge of AGTC:B36 Coordinates of that on ART2080.dwg are (measured using e drawings PRO): X: 1560744.5 mm Y: 2138902.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK - All optics positions verified 20200903. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the downstream (closer to AGTS:Q9) edge of AGTC:B36 Coordinates of that on ART2080.dwg are (measured using e drawings PRO): X: 1560744.5 mm Y: 2138902.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. Sequence ends at the edge of AGTE:B1 closer to AGTS:Q13. Coordinates of that on ART2080.dwg are (measured using e drawings PRO): X: 1611544.625 mm Y: 2138902.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK - All optics positions verified 20200903. All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the edge of AGTE:B1 closer to AGTS:Q13. Coordinates of that on ART2080.dwg are (measured using e drawings PRO): X: 1611544.625 mm Y: 2138902.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. Sequence ends at the downstream (closer to AGTY:B1) edge of the AGTS:Q20 skimmer. Coordinates of that on ART2080.dwg are (measured using e drawings PRO): X: 1672951.25 mm Y: 2138902.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK 20200226: All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf NOTHING ELSE CHECKED. Sequence starts at the downstream (closer to AGTY:B1) edge of the AGTS:Q20 skimmer. Coordinates of that on ART2080.dwg are: X: 1672951.25 mm Y: 2138902.75 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. Sequence ends at the downstream (closer to AGTY:Q13) edge of AGTNY:B4. Coordinates of that on ART2080.dwg are: X: 1693204.125 mm Y: 2262221.25 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. SK - All optics positions verified 202000226 All quad effective lengths confirmed based on TRI-BN-19-22 by Rick Baartman: http://lin12.triumf.ca/text/design_notes/b2019_22/note.pdf Sequence starts at the downstream (closer to AGTY:Q13) edge of AGTNY:B4. Coordinates of that on ART2080.dwg are: X: 1693204.125 mm Y: 2262221.25 mm Note that the units on this drawing appear to be messed up. To get an actual distance in mm the units given on drawing need to be divided by 25.4. call FIT( 1, 1, 1, 0.000, 10.000, 1) call FIT( 1, 3, 3, 0.000, 10.000, 1)